>> Catalog Main : Power Products : PST
ONLINE CATALOG
PST-SB 250-650
Oil-Filled
Substation Class

For a *.pdf of the current product catalog pages click HERE.
ApplicationType PST transformers are designed to provide remote location station power needs up to 100 kVA as well as relaying performance or metering accuracy at 0.3% when loaded with IEEE burdens through ZZ. They are oil filled and hermetically sealed with a dry Nitrogen cushion.
Fabrication
Standard transformer tanks are manufactured from mild steel, protected with a zinc rich primer and acrylic top coat ANSI-70 gray paint suitable for withstanding the most rigorous environmental conditions. Porcelain clad bushings are one-piece wet process type designed to exceed IEEE standard creep and strike distances.
Magnetic circuits
All ITEC voltage transformers use high grade highly permeable silicon steel cores. Repeatability of accuracy performance from one transformer to another is dependent on consistent performance of quality core steel. For this reason all magnetic cores used in ITEC transformers are from high quality suppliers.
Primary terminals
Standard terminal for ITEC voltage PST model transformers is a four hole spade. Primary terminations are conveniently located at the top of the transformer for hook-up to high voltage lines.
Secondary terminals
Secondary terminations are brought into the low voltage compartment and secured to low voltage terminations for convenient connections. The low voltage compartment is suitably weatherproofed to maintain dry connections.
Drying and impregnation
In order to achieve the highest possible insulation integrity moisture content is minimized transformers are dried out and impregnated with transformer oil under vacuum in order to minimize moisture content. Dissipation factor readings are checked on each transformer at final test to insure proper drying has been achieved.
Testing
Every voltage transformer is tested in accordance with IEEE STD C57.13 (Latest revision). In addition ITEC tests each unit in accordance with NEMA 107. Extinction levels are required to be a minimum of 35% above operating voltage for all transformers.
Ground Connections
Each transformer is supplied with a NEMA 2-hole ground pad.
Nameplate Information
In addition to the nameplate, ratio information is stenciled onto the tank wall in 2" high numeric for remote identification..
OIL-23
Transformer Characteristics |
Catalog ID |
|||||||
BIL kV |
Nom - System Voltage |
Winding Ratio Power Meter |
Primary Voltage |
Power Sec.Voltage |
Sec.Voltage |
25 kVA |
50 kVA |
100 kVA |
One bushing for phase-to-ground application on three phase four wire GRD Y. Power windings only. |
||||||||
250 |
46000 |
110/221 N/A |
27600 |
250/125 |
N/A |
PA10250024025P0 |
PA10250024050P0 |
PA10250024099P0 |
350 |
69000 |
161/322 N/A |
40250 |
250/125 |
N/A |
PA10350035025P0 |
PA10350035050P0 |
PA10350035099P0 |
550 |
115000 |
276/522 N/A |
69000 |
250/125 |
N/A |
PA10550060025P0 |
PA10550060050P0 |
PA10550060099P0 |
650 |
138000 |
321/642 N/A |
80500 |
250/125 |
N/A |
PA10550070025P0 |
PA10650070050P0 |
PA10650070099P0 |
One bushing for phase-to-ground application on three phase four wire GRD Y. Power windings and meter winding Accuracy: 0.3@ W,X,Y,Z -ZZ Meter full winding thermal rating 6000 VA. |
||||||||
250 |
46000 |
110/221 & 240/400 :1 |
27600 |
250/125 |
115/69 |
PA10250024025M0 |
PA10250024050M0 |
PA10250024099M0 |
350 |
69000 |
161/322 & 350/600 :1 |
40250 |
250/125 |
115/67.08 |
PA10350035025M0 |
PA10350035050M0 |
PA10350035099M0 |
550 |
115000 |
276/522 & 600/1000 :1 |
69000 |
250/125 |
115/69 |
PA10550060025M0 |
PA10550060050M0 |
PA10550060099M0 |
650 |
138000 |
321/642 & 700/1200 :1 |
80500 |
250/125 |
115/67.08 |
PA10650070025M0 |
PA10650070050M0 |
PA10650070099M0 |

Specifications |
Description |
||||||
BIL |
250 |
350 |
550 |
650 |
1. 1/2" drain valve. |
8. Oil level indicator. |
|
A |
63" |
71" |
103" |
107" |
2. HO neutral bushing/removable ground strap. |
9. Stainless steel nameplate. |
|
B |
36.5" |
38.5" |
40" |
40" |
3. HO bushing guard. |
10. Mild steel tank. |
|
C |
28" |
33" |
56.5" |
56.5" |
4. Porcelain insulator, glaze ANSI 70 |
11. Lifting ears. |
|
D |
34" |
36" |
38" |
38" |
light gray. |
12. Secondary terminal box w/3 each |
|
E |
23" |
28" |
45.5" |
45.5" |
5. Expansion chamber. |
1 1/2" conduit knockouts. |
|
Weight (lbs) Net |
4200 |
4500 |
5000 |
5500 |
6. 3/4" NPT vacuum port-1/4" NPT pressure relief valve |
13. 2-hole NEMA Standard ground pad. |
|
| Weight Ship | 4700 | 5000 | 5500 | 6000 | relief valve. |
14. Baseplate with (4) |
|
Oil Volume (gal) |
95 |
130 |
170 |
175 |
7. Primary connection 4 -hole NEMA spade. |
Mounting holes. |
|
Min. Creep |
37" |
52" |
101" |
103" |
|||
Min. Strike |
23.5" |
25" |
37.5" |
41.5" |
|||
>> Catalog Main : Power Products : PST